Boilers
Treatment4Water supplies industrial water treatment chemicals for steam raising and hot water boilers.
Steam Boiler Chemicals
Treatment4Water provides a comprehensive range of formulated own-label products to treat industrial steam boilers. Our proven products address issues related to oxygen scavenging, metal passivation, internal conditioning, alkalinity and pH control, foaming, and steam line and condensate protection.
Hot Water Boiler Chemicals
Treatment4Water provides a comprehensive range of formulated own-label products to treat closed circuit hot water boilers. Our proven products address the issues of scale and corrosion problems, assuring efficient operation and increased longevity of your hot water boiler.
Steam Boiler Chemicals
Treatment4Water formulate own-label products to cover low, medium, and high pressure systems.
Our deep level of experience, knowledge, and expertise in this area is available to all our customers in the form of technical support, from product selection through to application advice, and troubleshooting guidance.
Our team of experts are on hand to give valuable selection and application guidance for all our products. Contact us for details of our own-label product range.
Product Guide: Steam Boiler Chemicals
SYN-PLEX
Properties
Dosing and Control
101: Alkalinity Builder
pH & Alkalinity correction in feed and boiler water Freezing Point 70C
Tannin reserves 120-160mg/L
105: Alkalinity Builder
pH & Alkalinity builder. Low Freezing Point < -100C
1.8(B/C + H-M) Minimum 200mg/L CaCO3 OH– alkalinity
113: Medium – High pressure Water Tube Boiler
2.8-2.7 Ratio Na:PO4 Co-ordinated /Congruent phosphate
Dependant on operating boiler pressure usually 15-30mg/L as PO4
114: Low Pressure Boiler
Calcium hardness precipitant suitable for high alkalinity feed waters
3.3 (B/C + 0.6H), 30 – 70mg/L as PO4
170: Boiler Water Conditioner
Polymer, Phosphate Sequestrant
4.2 (B/C + 0.6H), 30 – 70mg/L as PO4
178: All-in-One Product – Small Boilers
Phosphate, Polymer ,Tannin Reduced conductivity contribution
100mg/L of product to boiler to achieve a reserve of 30 – 70mg/L as PO4
178SE: All-in-One Product – Small Boilers
Phosphate, Polymer & Erythorbate. Metal passivator
100mg/L of product to boiler to achieve a reserve of 30 – 70mg/L as PO4
179: All-in-One Product – Small Boilers
Alkalinity builder, Phosphate, Polymer, Tannin reduced conductivity contribution
100mg/L of product to boiler to achieve a reserve of 30 – 70mg/L as PO4
SYN-OTROX
Properties
Dosing and Control
202: Oxygen Scavenger and Metal Passivator
Low solids, scavenger / metal passivator aids, MAGNETITE formation
Tannin reserves 120-160mg/L
216: Oxygen Scavenger
Catalysed liquid bisulphite. Sulphite reserves of 30-70mg/L in boiler
1.5(B/C + 8(O2)) 30-70mg/L as SO3
218: All Organic Passivator & Scavenger
Erythorbate solution 15mg/L reserve as Erythorbate for scavenging or 5mg/L reserve for passivation
50-150mg/L to boiler feed
223: Medium-High Pressure Boiler
Volatile oxygen scavenger / metal passivator (DEHA)
17.6:1mg/L O2. DEHA Reserve of 0.5mg/L in condensate
226: Medium-High Pressure Boiler
Non-volatile oxygen scavenger and metal passivator (Carbo-hydrazide)
55:1mg/L for 1mg/L O2 in feed water
SYN-AMINE
Properties
Dosing and Control
310: Steam Line and Condensate
Cyclo-hexylamine: High distribution ratio for long condensate lines
Monitor condensate @ pH8.5
2.5 x feed water alkalinity
330: Steam Line and Condensate
DiEthyl-Aminoethanol (DEAE): Mid range distribution ratio
Monitor condensate @ pH8.5
2.5 x feed water alkalinity
340: Steam Line and Condensate
Morpholine: Low distribution ratio for short condensate lines
Monitor condensate @ pH8.5
2.5 x feed water alkalinity
350: Steam Line and Condensate
Monitor condensate @ pH8.5
2.5 x feed water alkalinity
Monitor condensate @ pH8.5
2.5 x feed water alkalinity
Hot Water Boiler Chemicals
Scale and corrosion within a system can lead to blockages, reduced heat transfer efficiency, and decreased asset life expectancy. Our team of experts are on hand to give valuable selection and application guidance for all our products. Contact us for details of our own label product range.
Product Guide: Hot Water Boiler Chemicals
Hot Water Boiler Chemicals
Properties
Dosing and Control
202: Oxygen Scavenger and Metal Passivator
Low solids Scavenger / metal passivator aids MAGNETITE formation
Tannin reserves 120-160 mg/L
216: Oxygen Scavenger
Catalysed liquid bisulphite. Sulphite reserves of 30-70 mg/L in boiler
1.5(B/C + 8(O2) ) 30 – 70mg/L as SO3
223: Medium – High Pressure Boiler
Volatile Oxygen scavenger / metal passivator (DEHA)
17.6 : 1 mg/L O2. DEHA Reserve of 0.5mg/L in condensate.
179SE: All in One Product
Alkalinity builder, Phosphate, Polymer & Erythorbate. Metal passivator
100mg/L of product to boiler to achieve a reserve of 30 – 70mg/L as PO4
482: Inhibitor – Multi- metal Systems except Aluminium
Alkali, Polymer, Tannin
Fill up charge: 3 litres/m3, Maintain a Tannin reserve of 100 – 160 mg/L
386: Steam Line, Condensate and HPHW Systems
High distribution ratio amine plus oxygen scavenger and passivator
Monitor condensate @ pH8.5. 4 x feed water alkalinity. HPHW systems initial fill 1%
TD52: Inhibitor – Multi- metal Systems including Aluminium
Alkanolamine, Azole, Co-polymer, Molybdate, Phosphonate
Fill up charge: 2 litres/m3, Monitor MoO4 at ≥250mg/L
429: Inhibitor – Multi- metal Systems except Aluminium
Azole, Co-polymer, Molybdate, Nitrite
Fill up charge: 4 litres/m3, Monitor NaNO2 at 450-600mg/L
431: Inhibitor – Multi- metal Systems except Aluminium
Azole, Biocide, Co-polymer Nitrite, Phosphonate
Fill up charge: 4 litres/m3, NaNO2 maintain reserve 1,000mg/L
TD55: Inhibitor – Multi- metal Systems including Aluminium
Alkanolamines, Azole, Co-Polymers, PCA, Phosphonates
Total organic
alkalinity titration. Fill up charge: 3 litres/m3
483: Inhibitor – Multi- metal Systems except Aluminium
Alkali, Polymer, Tannin
Fill up charge: 3 litres/m3, Maintain a tannin reserve of 100 – 160 mg/L